E.O. Schweitzer Manufacturing - A Division Of SEL
EOS Voltage Sensors

What's New

arrow 2008 Product Catalog
white arrow RadioRANGER™ Flyer
white arrow RadioRANGER™ Wireless Fault Indication System Reduces Fault- Locating Time
White Arrow AutoRANGER™ Test Certificate: ANSI/IEEE Std. 495-1986
White Arrow Reducing Customer Outage Duration at We Energies
White Arrow Use FCIs With Other SEL Distribution Products to Increase Reliability
Overhead Fault Indicator Model Option Table
little arrow Fault Indicator Model Option and Part Number Tables
SEL LINAM Current Reset Fault Indicator Flyer
little arrow AutoRANGER Field Guide

 

 

 

  Home
  About Us
  Products
  Applications
arrow  Installation Instructions
  Events
  Sales Offices
  News and Job Openings

E.O. Schweitzer Manufacturing
A Division of SEL

  little white arrow  Fault Indicators
  little white arrow  Voltage Indicators
  little white arrow  Other Products for the Industry

Tel.: 1-847-362-8304
Fax: 1-847-362-8396
Email: csr@eosmfg.com

 

 

Three-Phase Voltage Sensors

Overview

Use three-phase voltage sensors to detect primary system voltage on main and alternate sources for use in automatic transfer schemes. Voltage sensors detect voltage via the separable connector termination test point. The presence of system voltage is indicated via an electrically-isolated contact. E. O. Schweitzer Manufacturing makes and calibrates each voltage sensor as a complete custom solution for each application for delta- or wye-configured systems. Page two of the attached specification/installation sheets includes space for order-specific information to be filled out by the factory at the time of order.

pdf document  Learn more about the SEL Delta-Configured Voltage Sensor

pdf document  Learn more about the SEL Wye-Configured Voltage Sensor

 

Features
  • Isolated power supply: 24 VDC with a 50 mA maximum DC draw
  • Drop-out voltage = 75% of system voltage
  • Pull-in voltage = 90% of nominal system voltage
  • Three sensors, one on each phase, connect to a single junction box
  • Contacts on the delta sensor latch open when phase-to-phase system voltage on all three phases drops below 75%. The contacts latch closed when system voltage on three phases is above 90%.
  • The wye sensor's contacts latch open when phase-to-ground system voltage on any phase drops below 75%. The contacts latch closed when system voltage on three phases is above 90%.

 